Part Number Hot Search : 
SKY77550 A476M2 L9480VB MPX4250D LT0487 BAV89 17081CB 45FCT
Product Description
Full Text Search
 

To Download IBC-L01D0141 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 COMMUNICATIONS COMPONENTS
50/100 GHz, 100/200 GHz Passive Interleavers IBC Series
Key Features
* Low dispersion * Low insertion loss * High channel isolation * Wide clear bandwidth * Full C- or L-band coverage * Athermal design
Applications
* Extend existing network capacity * Bridge existing and new DWDM platforms * Ultradense DWDM mux/demux and add/drop applications * Bidirectional networks * Optical signal comb filtering
The JDSU interleaver is a terabit-enabling technology for ultradense wavelengthdivision multiplexing (DWDM) applications. When used in the mux configuration, the interleaver combines two streams of periodic optical signals (one stream carries even channels and the other carries odd channels) into one stream of signals of half the channel spacing. When used in the demux configuration, the signal is separated into two complementary streams (even and odd channels) of twice the channel spacing. The low dispersion interleaver, based on patented technology, features a wide clear bandwidth, minimal thermal drift, low insertion loss, low ripple, and low polarization dependent loss (PDL). Temperature control is not required.
NORTH AMERICA: 800 498-JDSU (5378)
WORLDWIDE: +800 5378-JDSU
WEBSITE: www.jdsu.com
IBC SERIES
2
Package Drawing and Port Designations
H
Port 'x' W Port 'y' Port 'z' 17.2mm (Collimators)
L
Channel Spacing
Device Type L
Dimensions W 25.2 mm 25.2 mm
H 12.4 mm 12.4 mm
X Odd Even
Port Designations Y Common Common
Z Even Odd
50/100 GHz 100/200 GHz
Notes:
Mux/Demux Mux/Demux
120.2 mm 84.2 mm
1. See Table 1 below for channel designation of the even and odd ports. Detailed package drawings available on demand. 2. Excluding collimators and strain reliefs. 3. Excluding mounting holes. Please contact JDSU for detailed drawings.
Table 1: Channel Designation of Even and Odd Ports
Channel Spacing /ITU Offset 50/100 GHz on ITU 50/100 GHz, 25 GHz offset 100/200 GHz on ITU 100/200 GHz, 50 GHz offset
C Band Even Port Frequency 192.000 to 196.000 THz 192.025 to 195.925 THz 192.000 to 196.000 THz 192.050 to 195.850 THz
C Band Odd Port Frequency 192.050 to 195.950 THz 192.075 to 195.975 THz 192.100 to 195.900 THz 192.150 to 195.950 THz
L Band Even Port Frequency 186.800 to 191.000 THz 186.825 to 190.925 THz 186.800 to 191.000 THz 186.850 to 190.850 THz
L Band Odd Port Frequency 186.850 to 190.950 THz 186.875 to 190.975 THz 186.900 to 190.900 THz 186.950 to 190.950 THz
IBC SERIES
3
Specifications
Parameter Wavelength (C band, for end channel ITUs) Wavelength (L band, for end channel ITUs) Frequency (C band, for end channel ITUs) Frequency (L band, for end channel ITUs) Number of channels Clear bandwidth (standard) Clear bandwidth (wideband) Insertion loss within clear bandwidth1, 2 Ripple within clear bandwidth2, 3 PDL within clear bandwidth2, 4 Insertion loss uniformity2, 5 Adjacent channel isolation2, 6 Return loss1 Directivity Polarization mode dispersion Chromatic dispersion within clear bandwidth Optical power7 Operating temperature Fiber type
1. Without connector. 2. Over all operating temperatures and states of polarization (SOP). 3. Measured at any given SOP. 4. Difference between insertion loss at any two SOP, measured at a given wavelength.
50/100 GHz Mux/Demux 1529.55 to 1561.42 nm 1569.59 to 1604.88 nm 196.000 to 192.000 THz 191.000 to 186.800 THz 80 8 GHz 10 GHz 2.0 dB 0.4 dB 0.4 dB 0.5 dB 14 dB (Mux)/25 dB (Demux) 45 dB 55 dB 0.2 ps 20 ps/nm 250 mW 0 to 65C 900 m tight buffer SMF-28
100/200 GHz Mux/Demux 1529.55 to 1561.42 nm 1569.59 to 1604.88 nm 196.000 to 192.000 THz 191.000 to 186.800 THz 40 15 GHz N/A 2.0 dB 0.4 dB 0.4 dB 0.5 dB 14 dB (Mux)/25 dB (Demux) 45 dB 55 dB 0.2 ps 15 ps/nm 250 mW 0 to 65C 900 m tight buffer SMF-28
Minimum Minimum Minimum Maximum Maximum Maximum Maximum Minimum Minimum Minimum Maximum Maximum Maximum
5. Difference between the maximum insertion loss over any two clear bandwidths, at any given SOP, and at any operating temperature. 6. Measured over clear bandwidth of both adjacent channels. 7. Across C and L band only.
IBC SERIES
4
Ordering Information
For more information on this or other products and their availability, please contact your local JDSU account manager or JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide, or via e-mail at customer.service@jdsu.com.
Sample: IBC-C05D01410
IBCCode C L Wavelength Range C band L band Code 1 5 Code 0 W Design Type1 Standard Wideband Narrower Channel Spacing 100 GHz 50 GHz Code 0 5 A
14
Center Wavelength Aligned with ITU grid2 50 GHz offset (for 100/200 GHz) 25 GHz offset (for 50/100 GHz) Code 1 5 Fiber Length3 100 cm 50 cm
Code D M
Function Demux Mux
Code 0 1 2 4 B
Connector No connector FC/APC SC/UPC FC/UPC LC/PC
1. Dual stage modules available. Please contact JDSU for further details. 2. Standard. 3. Tolerance of 0.1 meter.
NORTH AMERICA: 800 498-JDSU (5378)
WORLDWIDE: +800 5378-JDSU
WEBSITE: www.jdsu.com IBC.DS.CC.AE September 2008
Product specifications and descriptions in this document subject to change without notice. (c) 2008 JDS Uniphase Corporation 10113978 009 0908 SMF-28 is a registered trademark of Corning Incorporated. LC is a registered trademark of Lucent Technologies.


▲Up To Search▲   

 
Price & Availability of IBC-L01D0141

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X